{"product_id":"glensound-gdc-6432-dcu-src2-sample-rate-converters-per-aes-input","title":"Glensound GDC-6432-dCU\/SRC2 | Sample rate converters per AES input","description":"\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e This SKU is an accessory \/ option \/ add-on related to another Glensound product and not a standalone device.\u003c\/p\u003e\u003cp\u003eSample rate converters per AES input Digital Commentators' Unit\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDigital commentators' unit of Glensound Digital Commentary\u003c\/li\u003e\n\u003cli\u003eIndependent controls for 3 commentators\u003c\/li\u003e\n\u003cli\u003e8 inputs to each commentators' headphones\u003c\/li\u003e\n\u003cli\u003e4 talkback circuits\u003c\/li\u003e\n\u003cli\u003eAll buttons have programmable configuration\u003c\/li\u003e\n\u003cli\u003eAuxiliary AES\/analogue inputs and outputs\u003c\/li\u003e\n\u003cli\u003ePowered by coax or copper Ethernet link to dCCU\u003c\/li\u003e\n\u003cli\u003eSignal to noise ratio better than 100dBFS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"tab-content\" id=\"tab2content\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe GDC 6432 is a 2 part digital commentary system, consisting of a 3 commentator\/producer unit (dCU3) and a 1u 19inch base unit(dCCU). \u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003edCU\/3 digital Commentators' Unit\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThe dCU\/3 has complete facilities for 3 separate commentators. Each commentator can connect dynamic, ribbon, or condenser microphones (48v switchable), and connect a pair of headphones via 6.35mm sockets.\u003cbr\u003e\u003cbr\u003eEach commentator has 8 independently adjustable level feeds to create their own preference of headphone mix. These inputs typically include, programme, feedback, international sound, co-ordinator, and technician - for example, although they can of course be anything. Each input can be placed at the preference of the commentator, to either or both ears. There are also 4 talkback circuits selectable per commentator.\u003cbr\u003e\u003cbr\u003eThere is an additional line level input on the front panel that has its own on\/off and is switchable onto the talkback circuits.\u003cbr\u003e\u003cbr\u003eOperation of all dCU\/3 switches is configurable using the Switches software.\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"..\/..\/..\/..\/assets\/scripts\/timthumb.php?src=\/assets\/images\/library\/526e72a00a7e8-Dc6432dcu%20Angle%20BAN.jpg\u0026amp;w=1200\" width=\"400\"\u003e\u003cbr\u003e\u003cbr\u003eThere are 8 inputs and 8 outputs on the dCU\/3. Not all of these are pre-assigned and are available as auxiliary IO. On the rear panel there are analogue and AES inputs and outputs.\u003cbr\u003e\u003cbr\u003eThe dCU\/3 is powered via the link to the dCCU using coax or copper Ethernet. If the fibre link is used the dCU\/3 is powered via an external DC supply. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDigital Link\u003c\/strong\u003e\u003cbr\u003eThe link between the dCU\/3 and the dCCU carries 8 channels of bi-directional audio at 24bit 48 kHz. There are 3 options on the type of link; 1) Coax, giving a 400m range and carrying audio and the power for the dCU3, 2) Copper Ethernet, giving a 100m range and carrying audio and power for the dCU3, or 3) Fibre Ethernet, giving kilometres of range with the dCU3 being powered locally.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEthernet Remote Control\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"..\/..\/..\/..\/assets\/scripts\/timthumb.php?src=\/assets\/images\/library\/526e8c7d9ea15-Dc6432dccurem%20Front%20BAN.jpg\u0026amp;w=1200\" width=\"400\"\u003e\u003cbr\u003e\u003cbr\u003eYou can remote control and monitor, levels and audio via any Ethernet connected PC. The remote control facility operates within a PC browser as a Java application and connects to the GDC 6432s internal web browser via IP. The visual mixer representation shows real time settings of the dCU3 and the dCCU, allowing engineers to see the commentators pot positions, monitor and adjust mic gain levels, turn on or off mic phantom power, monitor any input into the dCU3, and adjust the output mix level, for example. Whats more an engineer is an active participant in the system, as the remote link also carries uncompressed audio (2mb sec), allowing the engineer to talkback on any of the 4 circuits, talkback to any commentator, or record the line idents, for example. This is suitable for remote control inside an OB truck, or via a high capacity WAN back to an International Broadcast Centre (IBC). Using an ISDN or IP codec, this remote audio link could easily be transmitted worldwide.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDigital Router\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"..\/..\/..\/..\/assets\/scripts\/timthumb.php?src=\/assets\/images\/library\/526e8d72da94f-matrixl.jpg\u0026amp;w=1200\" width=\"400\"\u003e\u003cbr\u003e\u003cbr\u003eThe audio inputs and outputs on the dCU\/3 have the facility for profiling to match the required application. On the dCU3 there are 8 audio inputs and 8 audio outputs. The routing of this audio is configurable via a digital router\/mixer and the IO of the dCCU allowing hundreds of combinations of audio routing profiles that can be triggered by, or trigger, DC loops and can be triggered by button switches or positions. The Glensound default profile is the result of many years of experience in the commentary world and will meet the requirement of most users. However, if you want to configure the routing for your specific use, the power and flexibility is there to do it. Configurations are simply via a USB PC connection.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003edCU3 Switch Profile\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg alt=\"\" src=\"..\/..\/..\/..\/assets\/scripts\/timthumb.php?src=\/assets\/images\/library\/526e9264a607f-Dc6432dccuswitch%20Front%20BAN.jpg\u0026amp;w=1200\" width=\"400\"\u003e\u003cbr\u003e\u003cbr\u003eAll switches on the dCU3 can be configured. Switches can be locked on the phantom power switch for example if you always use condenser microphones, thus stopping problems if the commentator inadvertently turns it off! Talkback buttons can interrupt a channel on switch or turn it off requiring it to be manually selected again. Talkback buttons can be on\/off, push to talk, or lazy Glensounds special mode of offering push to talk if the button is held, and on\/off if it is tapped. Store multiple configuration files off line, and simply drag and drop via USB to change.\u003c\/p\u003e \u003c\/div\u003e\u003ch4\u003eTechnical Information\u003c\/h4\u003e\u003cdiv class=\"tab-content\" id=\"tab4content\"\u003e\n\u003cp\u003eDigital Commentators Unit For GDC 6432 System\u003cbr\u003eAll figures calculated with phantom power off. At line up, phantom power adds 10dB gain\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eHeadroom @ line up:\u003c\/strong\u003e 36dB\u003cbr\u003e-58 on input = -18dBu on uncompressed output\u003cbr\u003e-58 on input = 0dBu on compressed output\u003cbr\u003e-22 on input = +18dBu on compressed output (max before clipping)\u003cbr\u003e-22 on input = +18dBu on uncompressed output (max before clipping)\u003cbr\u003e-12 with phantom on\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGain at line up\u003c\/strong\u003e\u003cbr\u003e= 40dB to uncompressed\u003cbr\u003e= 58dB to compressed\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMax Gain\u003c\/strong\u003e\u003cbr\u003e=88dB to compressed (for 0dBu)\u003cbr\u003e=88db to uncompressed (for -18dBu)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMin Gain\u003c\/strong\u003e\u003cbr\u003e=32dB to compressed (for 0dBu)\u003cbr\u003e=32dB to uncompressed (for -18dBu)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMax input level before clipping at min gain\u003c\/strong\u003e = +4dBu\u003cbr\u003e\u003cstrong\u003eMax input level before clipping at max gain\u003c\/strong\u003e= -52dBu\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eNoise (Unweighted RMS at line up):\u003c\/strong\u003e\u003cbr\u003eAnalogue:\u003cbr\u003e-80dBu compressed\u003cbr\u003e-99dBu uncompressed\u003cbr\u003eDigital:\u003cbr\u003e\u0026gt;-100dBFS compressed\u003cbr\u003e\u0026gt;-120 dBFS uncompressed\u003c\/p\u003e \u003c\/div\u003e\u003ch4\u003eOfficial Resources\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/product-details\/gdc-6432-dcu3\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOfficial Reference Page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/assets\/library\/52c696119d872-The%20Complete%20Commentary%20Guide%20Web%20Sized.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCommentary -The Complete Commentary Guide Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/assets\/library\/525ff3064ce47-Tech%20Spec%20MW%20modified%20for%20corel.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eCommentary Tech Spec\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/assets\/library\/52653ca3aac31-GDC6432%20Info%20Complete%20WEB.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eGDC 6432 Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/assets\/library\/52654893bed5c-Coax%20Cable%20spec.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eGDC 6432 Cable Spec\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/assets\/library\/5265404e95837-Recall_gain_ph_pwr_sw_installation_guide.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eGDC 6432 dCU\/3 Recall Gain Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/assets\/library\/5265401427670-dCUconfig.zip\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eGDC 6432 dCU\/3 Switch Profile Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/assets\/library\/52653cf538677-GDC-6432-dCU3_Manual_Content_V2.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eGDC 6432 dCU3 Manual Version 2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/assets\/library\/5265424997150-integrationexample.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eGDC 6432 Integration Example\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.glensound.co.uk\/assets\/library\/5773b2568aca0-Glensound%20Catalogue%2019%20LQ.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOfficial Glensound Catalogue PDF\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Glensound","offers":[{"title":"Default Title","offer_id":53671427146069,"sku":"GDC-6432-dCU\/SRC2","price":81.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1033\/6993\/3141\/files\/Glensound_placeholder.jpg?v=1776030653","url":"https:\/\/tvpro.lt\/products\/glensound-gdc-6432-dcu-src2-sample-rate-converters-per-aes-input","provider":"tvpro.lt – Broadcast \u0026 Pro Video Equipment Online Store","version":"1.0","type":"link"}